Cor-60 Hidden Sash System with thermal break

System because of its design blade profiles keeps concealed from the outside, so it is impossible to distinguish which areas still have openings.
Hinged windows European channel composed of aluminum alloy profiles and heat treated 6063 T-5.
Possibility of all openings except the outer opening.
 
Frame and leaf have a depth of 60 mm. The average thickness of the aluminum is 1.6 mm.
 
The aluminum profiles are provided with thermal break obtained by inserting insulating tubular rods 24 mm polyamide 6.6. deep reinforced with 25% glass fiber.
 
Sealing system for EPDM triple.
 
Maximum glazing: 28 mm.
 
Maximum sound insulation Rw = 41 dB
 
Transmittance / Zones C.T.E. ;
 
UH from 1.3 (W / m².K)
Check type, size and glass
 
CTE- * Suitable for climatic zones: ABCDE α
* Depending on the transmittance of the glass.
 
Reached on a test bench * Categories:
 
Air permeability according to UNE-EN 12207: 2000 Class 4
Water tightness according to UNE-EN 12208: 2000 Class 9A
Wind resistance according to UNE-EN 12210: 2000 Class C5
 
* Reference test window x 1.16 m 1.13. 1 sheet

Cor-3500 System with Thermal Break

windows/doors comprising of 6063 aluminium alloy profiles with T5 thermal treatment.

The frame and sash are 55 mm & 63 mm deep respectively both in windows as in doors. The average aluminium profile wall thickness is 1.5 mm. in windows and 1,7 mm. in doors.

The aluminium profiles are provided with a thermal break which is achieved by inserting 24 mm wide 6.6 polyamide isolation strips which are reinforced with 25% fibre glass.

Maximum glazing: 40 mm.

Maximum accoustic insulation Rw=46 dB

Transmittance
Uw from 1,1 (W/m²K)
Please consult typology, dimensions and glass

Classifications achieved at test centre*:

Air permeability according to EN 12207:2000 Class 4
Water tightness according to EN 12208:2000 Class E1200
Wind resistance according to EN 12210:2000 Class C5


* Test reference 1,20 x 1,20 m. 2 Sashes

Cor-60 System with Thermal Break

windows/doors comprising of 6063 aluminium alloy profiles with T5 thermal treatment.

The frame and sash are 60 mm & 68 mm deep respectively both in windows as in doors. The average aluminium profile wall thickness is 1.6 mm in windows and doors.

The aluminium profiles are provided with a thermal break which is achieved by inserting 24 mm wide 6.6 polyamide isolation strips which are reinforced with 25% fibre glass.

Maximum glazing: 45 mm.

Maximum accoustic insulation Rw=48 dB

Transmittance

Uw from 1,0 (W/m²K)

Please consult typology, dimensions and glass

Classifications achieved at test centre*:

Air permeability according to EN 12207:2000 Class 4
Water tightness according to EN 12208:2000 Class E1200
Wind resistance according to EN 12210:2000 Class C5


* Test reference 1,20 x 1,16 m. 2 Sashes.
 

Cor-80 Industrial System with Thermal Break

A new concept of a Euro-Groove hinged system capable of reaching the maximum levels of weather tightness, energy saving and acoustic protection with reduced assembly and fabrication time. With 80mm of frame depth, it responds to the most severe climatic demands, and provides an unbeatable degree of energy efficiency thanks to its minimal window transmission value (UH) that can reach 0.8W/m²K. These minimum values are achieved thanks to the perfect design of the thermal break zone with 45mm tubular polyamide strips as well as the incorporation of cross-linked polyolefin both in the glazing space as well as the interior of the frame and sash.

Its great glazing capacity of up to 65mm allows for the use of energy efficient glazing and compositions of large thicknesses as well as double chambers that gives excellent thermal  and acoustic performance (up to 46dB of noise protection) that translates in to maximum energy saving and total interior comfort. The performance achieved in the AEV test, has shown this window to have the best water tightness performance, air permeability and wind resistance in order to guarantee the greatest protection against the most adverse atmospheric agents. The simplicity in its assembly and less labour time, allows for a more industrialized fabrication resulting in a final saving of time and cost.

TECHNICAL DATA :

Accoustic insulation

Maximum glazing: 65 mm

Maximum accoustic insulation: Rw = 46 dB

Transmittance

Uw from 0,8 (W/m²K)

Please consult typology, dimensions and glass

Compliance Zones of RCCTE * I1 I2 I3
*Depending on the transmission coefficient thermal glass

Opening possibilities

Open in: Practicable, turn-tilt, parallel tilt, hinged

Open Out: Practicable, projecting-sliding

             

Sections / Profile thickness

Sections:

· Frame – 80 mm
· Sash – 88 mm

Profile thickness:
· Window – 1,5 mm
· Door – 1,7 mm

Polyamide strip length: 45 mm

Maximum dimensions / Maximum weight

Maximum dimensions:
Width (L) = 1.600 mm
Height (H) = 2.600 mm
*Single sash window, turn-tilt

Maximum weight/sash: 120 Kg

Please consult regarding maximum weight and dimensions for other opening types

Categories achieved at test centre

Air permeability (EN 12207:2000): Class 4

Water tightness (EN 12208:2000): Class E1950

Wind resistance (EN 12210:2000): Class C5

Reference test: 1, 23 m x 1,48 m. 2 sashes.

Finishes

· Possibility of dual colour

· Colour powder coating (RAL, mottled & rough)

· Wood effect powder coating

· Anti-bacterial powder coating

· Anodized
Cor-70 CC16 System with Thermal Break

Cor-70 CC16 System with Thermal Break

A hinged 70 mm window system with a potent insulation capacity and with a transmission value from only 0.8W/m²K which has been achieved thanks to the perfect combination and design of aluminium profiles, 35mm tubular polyamide rods, E.P.D.M tubular water tightness gaskets and a system of polyolefine foam that is fitted around the glazing space perimeter.

Possiblity of straight and chamfered sashes and straight, chamfered or curved beads.

With its large glazing capacity of up to 58mm it presents to this system some excellent accoustic and thermal features allowing the use of large glazing thicknesses and energy efficiencies. There is the possibility of integrating hidden hinges accessories

TECHNICAL DATA :

Accoustic insulation

Maximum glazing: 58mm

Maximum accoustic insulation: Rw = 46 dB

Transmittance

Uw from 0,8 (W/m²K)

Please consult typology, dimensions and glass

Compliance Zones of RCCTE* I1 I2 I3
*Depending on the transmission coefficient thermal glass

Opening possibilities

Open In:
– Practicable, turn-tilt, folding, parallel tilt, hinged

Open Out:
– Practicable, projecting-sliding



Sections / Profile thickness

Sections:
· Frame – 70 mm
· Sash – 75 mm

Profile thickness:
· Window – 1,5 mm
· Door – 1,7 mm

Polyamide strip width: 35 mm

Maximum dimensions / Maximum weight

Maximum dimensions:
Width (L) = 1.600 mm
Height (H) = 2.800 mm
*Single sash window, turn-tilt

Maximum weight/sash: 150 Kg

Please consult regarding maximum weight and dimensions for other opening types

Categories achieved at test centre

Air permeability (EN 12207:2000): Class 4

Water tightness (EN 12208:2000): Class E1500

Wind resistance (EN 12210:2000): Class C5

Reference test: 1,23 m x 1,48 m. 2 sashes.

Finishes

· Possibility of dual colour

· Colour powder coating (RAL, mottled & rough)

· Wood effect powder coating

· Anti-bacterial powder coating

· Anodized
Cor-70 Hidden Sash System with Thermal Break

Cor-70 Hidden Sash System with Thermal Break

A new Euro-Groove concealed sash window design with slim profiles that are characterized by a seen surface of only 66mm from the exterior that maximises the glazing surface and is able to reach 85% of the total window glazing. This characteristic provides an extraordinary increase in luminosity in the inside of the dwelling. Its design allows for the hidden sash to be maintained from the outside in such a way that it is impossible to distinguish from the fixed zones that the opening has and therefore achieving perfect homogeneity in the façade’s style.

A 35 mm thermally broken area and the insertion of polyolefin sponge in the frame and sash allows it to reach values of up to 1,0W/m²K of transmission in the space and therefore maximising its energy efficiency. These high thermal performances are completed with an increased level of sound insulation that this system achieves thanks to the possibility of installing glazing units of up to 40mm in thickness. The classifications achieved in the AEV tests go to prove that the system has excellent water tightness, air permeability and wind resistance values in order to obtain increased protection against the most unfavourable weather conditions.

TECHNICAL DATA:

Accoustic insulation

Maximum glazing: 40 mm

Maximum acoustic insulation: Rw = 46 dB

Transmittance/Zones RCCTE

Uw from 1,0 (W/m²K)

Please consult typology, dimensions and glass

Compliance Zones of RCCTE* I1 I2 I3
* Depending on the heat transfer coefficient of the glass

Opening possibilities

Open In:
– Practicable  1 or 2 sashes
– Turn-tilt 1 or 2 sashes



Sections / Profile thickness

Sections:
· Frame – 70 mm
· Sash – 60 mm

Profile thickness:
· Window – 1,9 mm

Polyamide strip length: 35 mm

Maximum dimensions / Maximum weight

Maximum dimensions:
Width (L) = 1.300 mm
Height (H) = 2.400 mm
*Single sash window, turn-tilt

Maximum weight/sash: 120 Kg

Please consult regarding maximum weight and dimensions for other opening types 

Categories achieved at test centre

Air permeability (EN 12207:2000): Class 4

Water tightness (EN 12208:2000): Class E1650

Wind resistance (EN 12210:2000): Class C5

Reference test: 1, 23 m x 1,48 m. 2 sashes.

Finishes

· Possibility of dual colour

· Colour powder coating (RAL, mottled & rough)

· Wood effect powder coating

· Anti-bacterial powder coating

· Anodized